Samsung Dryer hC2 error code
On gas dryers, the dryer found a fault in the gas ignition system: the burner isn't lighting. The dryer will tumble but produce no heat. Everything gas-side is technician-only work.
Also shown as: hC2, HC2
Last updated: October 8, 2026
What causes the hC2 error?
- Gas supply valve to the dryer is closed
- Igniter has failed
- Gas valve coils have failed
- Flame sensor has failed
- Ignition wiring loose or damaged
- Electronic control board has failed
How to fix Samsung hC2: step by step
Work through these in order, from simplest and safest first. Stop as soon as the code clears.
- Check the gas supply valve
Make sure the gas shut-off valve behind the dryer is fully open (handle parallel to the pipe). A valve bumped closed during cleaning is a common cause.Safety warning: If you smell gas, don't touch anything electrical. Leave the house and call your gas company. - Confirm gas is reaching the house
Check whether other gas appliances (stove, water heater) work. If none have gas, the problem is the supply, not the dryer. Call your gas supplier. - Power cycle the dryer
Unplug the dryer for 2 minutes, plug it back in, and try a heated cycle. That resets the ignition control before you assume a parts failure. - Clean the lint filter and vent
Severe airflow restriction can prevent proper burner operation. Clean the filter and check the vent hose for blockages, then retry.
When to call a technician
- hC2 returns with the gas supply confirmed on
- The igniter, gas valve coils, or flame sensor needs testing
- The electronic control board is suspect
- Any smell of gas. Leave and call the gas company first
Frequently asked questions
My gas dryer tumbles but there is no heat and hC2 shows. What failed?
The ignition sequence: the igniter, gas valve coils, or flame sensor isn't doing its job, so the burner never lights. Gas-side parts are technician-only.
Can I fix the igniter myself?
No. Gas ignition work involves the gas line and high-voltage ignition parts. That's strictly professional work.
Is hC2 the same as hC?
No. hC is a general overheating or heating fault. hC2 is specific to gas models and means the gas burner failed to ignite.
Sources
Every meaning and fix above was checked against official manufacturer documentation:
FixCode provides general troubleshooting information only. It is not professional repair advice. If you are unsure about any step, stop and call a qualified technician. Repairs done incorrectly can be dangerous and may void your warranty.