LG Dryer np error code

The dryer is not detecting current at the heater. The drum may turn, but the house wiring or power cord is not delivering proper power for heating.

Also shown as: np, nP, NP

Last updated: October 6, 2026

Quick answer: LG dryer error code np: no power reaching heater. The most common cause is power cord wired incorrectly at the terminal block. Try this first — check both breakers. If that does not clear it, power reset the dryer. If the code persists, call a qualified technician.

What causes the np error?

  • Power cord wired incorrectly at the terminal block
  • One leg of the 240V supply lost (tripped breaker)
  • Blown house fuse
  • Faulty wall outlet
  • Loose connections at the terminal block

How to fix LG np — step by step

Work through these in order, from simplest and safest first. Stop as soon as the code clears.

  1. Check both breakers
    An electric dryer needs 240V from a double breaker. If one side tripped, the dryer runs but never heats. Flip the dryer breaker fully off, then back on.
    Safety warning: If the breaker trips again immediately, stop and call an electrician.
  2. Power reset the dryer
    Unplug the dryer for a minute and plug it back in firmly. A loose plug can cause the same symptom.
  3. Inspect the power cord connection
    With the breaker OFF, remove the terminal block cover on the back and check that the cord wires are tight and on the correct terminals per the manual.
    Safety warning: Turn the breaker off first and verify no power before touching the terminal block. If you are unsure, call an electrician.

When to call a technician

Stop and call a qualified technician if any of these apply:
  • The breaker trips repeatedly
  • You see burning or melting at the outlet or cord
  • The terminal block looks burnt
  • There is no 240V at the outlet

Frequently asked questions

My dryer runs but there is no heat. Is that nP?

It fits perfectly. The motor runs on 120V, but the heater needs the full 240V.

Can a tripped breaker cause nP?

Yes, it is the most common cause. Dryers use a double breaker, and one side can trip silently.

Is nP the dryer's fault?

Usually not. It points at the house wiring, breaker, or the cord connection, not the heating element.