Goodman Furnace 3 (red LED) error code

The inducer fan, the small fan that pulls combustion air through the furnace, could not build enough draft pressure to close the pressure switch. Until the board sees that pressure, it will not start the ignition sequence at all.

Also shown as: 3 red flashes, three red flashes, fault code 3 red, inducer pressure fault

Last updated: October 8, 2026

Quick answer: Goodman furnace error code 3 (red LED): inducer could not build enough draft pressure. The most common cause is the pressure-switch hoses are blocked or pinched. Try this first: clear the intake and exhaust terminations. If that does not clear it, inspect the pressure-switch hoses.

What causes the 3 (red LED) error?

  • The pressure-switch hoses are blocked or pinched
  • The combustion-air intake or the exhaust flue is blocked
  • The inducer motor is weak or failing

How to fix Goodman 3 (red LED): step by step

Work through these in order, from simplest and safest first. Stop as soon as the code clears.

  1. Clear the intake and exhaust terminations
    Go outside and check the furnace's intake and exhaust pipes for leaves, snow, ice, nests, or debris. Clear anything blocking them.
  2. Inspect the pressure-switch hoses
    With the power off, check the small rubber hoses for kinks, cracks, or water trapped inside.
  3. Have the inducer and switch tested
    A technician can measure the actual draft pressure and test both the inducer motor and the pressure switch.

When to call a technician

Stop and call a qualified technician if any of these apply:
  • The vents are clear, but the code stays
  • The inducer fan sounds weak, loud, or never starts at all

Frequently asked questions

Can a blocked vent really stop the furnace?

Yes. The furnace refuses to fire unless it can prove exhaust gases are venting outside. A blocked flue is a carbon monoxide hazard, so the lockout is intentional.

Will this fix itself when snow melts?

Sometimes, if ice or snow was the blockage. If the code stays after the pipes are clear, the switch or the inducer needs testing.

Sources

Every meaning and fix above was checked against official manufacturer documentation:

FixCode provides general troubleshooting information only. It is not professional repair advice. If you are unsure about any step, stop and call a qualified technician. Repairs done incorrectly can be dangerous and may void your warranty.

Related error codes

All Furnace error codes across brands · All Goodman codes →