Goodman Furnace 2 (red LED) error code
The control board is reading pressure at a moment when it should be reading none. Either the pressure sensor's contacts are stuck closed, or its wiring is shorted.
Also shown as: 2 red flashes, two red flashes, red LED flashing twice, fault code 2 red
Last updated: October 8, 2026
What causes the 2 (red LED) error?
- The pressure sensor's contacts are stuck closed
- The sensor wiring is shorted or pinched
- The pressure sensor itself has failed
How to fix Goodman 2 (red LED): step by step
Work through these in order, from simplest and safest first. Stop as soon as the code clears.
- Power-cycle once
Turn the furnace off at the service switch, wait 30 seconds, then turn it back on. If the code clears and heat works, the sensor may have just stuck temporarily. - Check the sensor hoses
With the power off, look at the small rubber hoses running to the pressure sensor. Straighten any kinks and drain any trapped water. - Call a technician for testing
The sensor must be tested with a meter and replaced if it will not open. Shorted wiring needs professional repair too.Safety warning: Do not bypass or jumper the pressure switch. It is a safety device that proves the venting system is working.
When to call a technician
- The code comes back after a power cycle
- The sensor hoses look fine, but the fault stays
Frequently asked questions
What does the pressure sensor do?
It proves the inducer fan is moving combustion air through the furnace and pushing exhaust outside. If the control cannot trust that reading, it will not let the burners fire.
Can I just disconnect the sensor?
No. Bypassing a pressure switch defeats a critical safety check and can let the furnace run with blocked venting, which is a carbon monoxide risk.
Sources
Every meaning and fix above was checked against official manufacturer documentation:
FixCode provides general troubleshooting information only. It is not professional repair advice. If you are unsure about any step, stop and call a qualified technician. Repairs done incorrectly can be dangerous and may void your warranty.